International Mechanical Code Loose Leaf (IMC)

Special Price $137.65 Regular Price $152.95
In stock
Product Code
3300L

International Mechanical Code Loose Leaf 2024 Edition

The 2024 International Codes® (I-Codes®) have undergone substantial formatting changes as part of the digital transformation strategy of the International Code Council® (ICC®) to improve the user experience.

The changes, promoting a cleaner, more modern look and enhancing readability and sustainability, include:

  • Single column text format and modernized font styles improves readability
  • QR Codes replace vertical margin sidebars and arrows to identify code changes more accurately
  • Shading for table headers and notes improves locating tables and applicable notes
  • Grouping of associated content brings tables and figures immediately after the parent section
  • Users have capability to validate authenticity of their book and register it with the ICC to receive incentives.

The International Mechanical Code (IMC®) establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions. The IMC® was developed with broad-based principles that make possible the use of new and innovative materials, methods and design.

Important changes in the 2024 IMC include:

  • Provisions prohibiting the use of domestic ductless range hoods in Groups I-1 and I-2 were removed.
  • An identification requirement was added for Group A2L and B2L refrigerants.
  • The requirements for machinery rooms containing Group A2L refrigerants were changed and Group B2L refrigerants were added to the provisions.
  • Limits for the use of Group A1 and A2L refrigerants changed in high probability systems used for human comfort, unless permitted as excepted.
  • UL 2158A Standard was added to the requirements for commercial dryer exhaust.
  • Ventilation requirements for outpatient healthcare facilities to match the requirements in ASHRAE 62.1-2019.
  • Addition of a new minimum landing at the roof hatch for personnel to safely use the hatch when accessing the roof for repair and maintenance.
  • Addition of a new testing option for grease ductwork.
  • Requirements for steam baths were added.
  • A new standard requirement for refrigeration systems containing carbon dioxide was added.

9781959851776, 9781609839659, 9781609837426, 9781609834784

More Information
Price$152.95
Customer Service

We're Here To Help!

Call us anytime during our customer service hours...


Monday through Friday - 8:30 am to 4:30 pm (Pacific)
Saturday - 9am to 1pm (Pacific)

Order Questions:

 

TOLL FREE, 800-273-7375 (Outside the U.S. call 818-887-7828).

Our Address:


8001 Canoga Avenue
Canoga Park, CA 91304 US
Phone: 800-275-2665
Fax Your Order
818-887-7990
Print Our Fax Order Form

Description

International Mechanical Code Loose Leaf 2024 Edition

The 2024 International Codes® (I-Codes®) have undergone substantial formatting changes as part of the digital transformation strategy of the International Code Council® (ICC®) to improve the user experience.

The changes, promoting a cleaner, more modern look and enhancing readability and sustainability, include:

  • Single column text format and modernized font styles improves readability
  • QR Codes replace vertical margin sidebars and arrows to identify code changes more accurately
  • Shading for table headers and notes improves locating tables and applicable notes
  • Grouping of associated content brings tables and figures immediately after the parent section
  • Users have capability to validate authenticity of their book and register it with the ICC to receive incentives.

The International Mechanical Code (IMC®) establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions. The IMC® was developed with broad-based principles that make possible the use of new and innovative materials, methods and design.

Important changes in the 2024 IMC include:

  • Provisions prohibiting the use of domestic ductless range hoods in Groups I-1 and I-2 were removed.
  • An identification requirement was added for Group A2L and B2L refrigerants.
  • The requirements for machinery rooms containing Group A2L refrigerants were changed and Group B2L refrigerants were added to the provisions.
  • Limits for the use of Group A1 and A2L refrigerants changed in high probability systems used for human comfort, unless permitted as excepted.
  • UL 2158A Standard was added to the requirements for commercial dryer exhaust.
  • Ventilation requirements for outpatient healthcare facilities to match the requirements in ASHRAE 62.1-2019.
  • Addition of a new minimum landing at the roof hatch for personnel to safely use the hatch when accessing the roof for repair and maintenance.
  • Addition of a new testing option for grease ductwork.
  • Requirements for steam baths were added.
  • A new standard requirement for refrigeration systems containing carbon dioxide was added.

9781959851776, 9781609839659, 9781609837426, 9781609834784

Recently Viewed
No recently views items
Clear All