NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems

Special Price $179.05 Regular Price $198.95
In stock
Product Code
NFPA2001

NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems 2022

The 2022 edition of NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems, includes essential requirements on how to properly purchase, design, install, test, inspect, approve, operate, and maintain engineered or pre-engineered gaseous agent fire suppression systems so they will function as intended when needed.

Revisions in the 2022 edition of NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems, include several major structural changes and new chapters, including the following:

  • Requirements moved from Chapter 1, "Administration", to Chapter 4, "General Requirements", to comply with the NFPA Manual of Style
  • Information on toxicological and physiological effects of clean agents moved from Annex A to a new stand-alone annex
  • System design requirements pertaining only to total flooding systems moved to a new stand-alone chapter and separated from requirements that apply to both total flooding and local application systems
  • Requirements for detection, actuation, alarm, and control systems moved to a new stand-alone chapter
  • New chapter on system impairment added
  • New annex on storage containers for vaporizing-liquid agents added

Several technical updates in the newest edition of the standard include the following:

  • New design criteria for 60-bar FK-5-1-12 systems
  • New design criteria for halocarbon blend 55 (HB-55) systems
  • Clarified terminology and requirements for clean agent design concentrations
  • New definition for deep-seated fire
  • New information on clean agent purity and the potential toxicity of impurities
  • Updated pressure curves for HFC-125
  • Updated total flooding quantity tables for inert gas agents
  • New requirement to consider potential effects of acoustic noise produced by a clean agent system where noise-sensitive equipment is present

2022 (9781455928118)

2018 (9781455919635)

More Information
Price$198.95
Customer Service

We're Here To Help!

Call us anytime during our customer service hours...


Monday through Friday - 8:30 am to 4:30 pm (Pacific)
Saturday - 9am to 1pm (Pacific)

Order Questions:

 

TOLL FREE, 800-273-7375 (Outside the U.S. call 818-887-7828).

Our Address:


8001 Canoga Avenue
Canoga Park, CA 91304 US
Phone: 800-275-2665
Fax Your Order
818-887-7990
Print Our Fax Order Form

Description

NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems 2022

The 2022 edition of NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems, includes essential requirements on how to properly purchase, design, install, test, inspect, approve, operate, and maintain engineered or pre-engineered gaseous agent fire suppression systems so they will function as intended when needed.

Revisions in the 2022 edition of NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems, include several major structural changes and new chapters, including the following:

  • Requirements moved from Chapter 1, "Administration", to Chapter 4, "General Requirements", to comply with the NFPA Manual of Style
  • Information on toxicological and physiological effects of clean agents moved from Annex A to a new stand-alone annex
  • System design requirements pertaining only to total flooding systems moved to a new stand-alone chapter and separated from requirements that apply to both total flooding and local application systems
  • Requirements for detection, actuation, alarm, and control systems moved to a new stand-alone chapter
  • New chapter on system impairment added
  • New annex on storage containers for vaporizing-liquid agents added

Several technical updates in the newest edition of the standard include the following:

  • New design criteria for 60-bar FK-5-1-12 systems
  • New design criteria for halocarbon blend 55 (HB-55) systems
  • Clarified terminology and requirements for clean agent design concentrations
  • New definition for deep-seated fire
  • New information on clean agent purity and the potential toxicity of impurities
  • Updated pressure curves for HFC-125
  • Updated total flooding quantity tables for inert gas agents
  • New requirement to consider potential effects of acoustic noise produced by a clean agent system where noise-sensitive equipment is present

2022 (9781455928118)

2018 (9781455919635)

Recently Viewed
No recently views items
Clear All